Soft Tissue Biopsy |
|
EasyLock |
Needle for Soft Tissues Biopsy by Aspiration as for "Menghini" modified |
EasyLock (PC) needle, is provided with an atraumatic sharpened cannula made with AISI 304 steel and a "Menghini" tip. The disposable device is used for soft tissues biopsy such as kidney, lymph nodes, liver and thyroid. Removable cannula with centimeter markings for a simple insertion depth evaluation.
The sliding stopper allows to easily determine the depth to reach. The internal echogenic marker enhances the ultrasound visibility avoiding the cells spread during the biopsy procedure. |
|
The device is provided with internal stylet with the following functions |
 |
To facilitate the device penetration without skin incision |
 |
To avoid the tissue penetration into the lumen of the cannula before reaching the target |
 |
To gradually transmit the created vacuum from the syringe, on the needle tip (thanks to a special processing present on the surface of the stylet) |
 |
To avoid the sample aspiration into the cylinder of the syringe, keeping the sample into the cannula and to facilitate the expulsion step |
|
|
The needle is provided with a sharpened Luer-lock to off er an added safety attachment to the syringe without vacuum loss.
Otpionally NeedleVise®safety device can be added (PCR code) |
|
Gauge |
Outer Diameter |
Code Length 70 mm |
Code Length 100 mm |
Code Length 120 mm |
Code Length 150 mm |
Code Length 200 mm |
18 |
1.27 |
PC1807 |
PC1810 |
PC1812 |
PC1815 |
PC1820 |
19 |
1.10 |
PC1907 |
PC1910 |
PC1912 |
PC1915 |
PC1920 |
20 |
0.90 |
- |
PC2010 |
PC2012 |
PC2015 |
PC2020 |
21 |
0.80 |
- |
PC2110 |
PC2112 |
PC2115 |
PC2120 |
22 |
0.70 |
- |
PC2210 |
PC2212 |
PC2215 |
PC2220 |
|
|
|
 |
|
|
|
EasyCut Coaxial |
|
The needle is provided with a sharpened Luerlock to off er an added safety attachment to the syringe EasyCut Coaxial (PC0C) is a combination of an EasyCut needle and a coaxial introducer needle with size and length studied to be exactly coupled to each other. The introducer may be left in position inside the patient, allowing the execution of multiple procedures. without vacuum loss. |
|
Gauge |
Diameter |
Code Length 70 mm |
Code Length 100 mm |
Code Length 150 mm |
Code Length 200 mm |
16 |
- |
PC0C1607 |
PC0C1610 |
PC0C1615 |
PC0C1620 |
18 |
1.27 |
PC0C1807 |
PC0C1810 |
PC0C1815 |
PC0C1820 |
20 |
0.90 |
|
PC0C2010 |
PC0C2015 |
PC0C2020 |
|
|
|
 |
|
|
HandCut |
|
Manual tru-cut needle for soft tissues biopsy with guillotine system |
HandCut (PM) needle is a disposable device for soft and fi brous tissues biopsy that need to be cut for their remotion.
The "Menghini" sharpening of the cannula, allows cutting and acquisition of the specimen. The stylet has a triple ultra-sharp tip to penetrate easily also into fi brous tissues and has a 20mm specimen notch for sample capturing.
Sliding stopper and centimeter markings on the cannula, to easily determine the insertion depth. |
|
The device is equipped with |
 |
Internal echogenic marker to enhance the ultrasound visibility avoiding cells spreading during the biopsy procedure |
 |
Length limitator to take samples of 10mm in length |
 |
Luer-lock that allows the connection to the syringe for Cytological aspiration |
|
|
Gauge |
Outer Diameter |
Code Length 75 mm |
Code Length 100 mm |
Code Length 114 mm |
Code Length 150 mm |
14 |
2.10 |
PM14075 |
PM1410 |
PM14114 |
PM1415 |
16 |
1.60 |
PM16075 |
PM1610 |
PM16114 |
PM1615 |
18 |
1.20 |
PM18075 |
PM1810 |
- |
PM1815 |
|
|
|
 |
|
|
|
Semicut |
Ultra-Light Semiautomatic Tru-Cut Needle for Soft Tissues Biopsy with Guillotine System with Non-Removable Cannula. |
Semicut is a disposable device provided with removable cannula with enhanced echo-visibility made with AISI 304 steel with a "Menghini" tip that allows an atraumatic precise cutting of the tissue. A sliding stopper and centimeter markings on the cannula surface allow an easily determination of the depth of insertion.
The biopsy specimen, can be taken with two diff erent length: 10mm or 20mm. Semicut, after cannula loading, can be used with a single hand, leaving the other free to handle other devices such as ultrasound guide etc. |
|
The stylet is equipped with |
 |
Ultra-sharp triple tip to penetrate easily also into fi brous tissues |
 |
A 20mm specimen notch for the sample capture |
|
|
Optionally, Semicut, can be provide with a coaxial introducer needle, with pyramidal tip stylet. Needle size, with international colour code, stamped on the handle of the needle.
Semicut, is the lightest semiautomatic device on the market; this characteristic is very important because allows the User to leave the device safely inserted into the patient without support it. |
|
Gauge |
Outer Diameter |
Code Length 70 mm |
Code Length 100 mm |
Code Length 150 mm |
Code Length 200 mm |
14 |
2.10 |
PD01407 |
PD01410 |
PD01416 |
PD01420 |
16 |
1.60 |
PD01607 |
PD01610 |
PD01616 |
PD01620 |
18 |
1.20 |
PD01807 |
PD01810 |
PD01816 |
PD01820 |
20 |
0.90 |
PD02007 |
PD02010 |
PD02016 |
PD02020 |
|
|
|
 |
|
|
|
Themy |
|
Automatic Disposable Device for Soft Tissues Biopsy |
Themy(R)(TY/TYS) is an automatic, disposable device equipped with a sequential advancement system of cannula and stylet. Themy is a lightweight device that off ers a spring loaded action that allows an accurate and easy penetration inside fi brous or calcifi ed lesions The device, is equipped with a AISI 304 stainless steel cannula with a "Menghini" sharpening that allows an atraumatic precise cutting of the tissue. The cannula is provided with centimeter markings to easy determine the depth of insertion for the safety of the patient.
Themy(R) is a very stable and ultralight automatic device. It can be provided in two versions with diff erent lenght of notch: 10mm (TYS) or 20 mm (TY). Needle size, with international colour code, is stamped on the hub and on the primary packaging. The stylet has a triple ultra-sharp tip to penetrate easily also into fi brous tissues. Possibility to take the sample with only one fi ring of the bottom.
Themy(R) is provided with two fi ring sequential trigger points, one in front and one at the back allowing to the doctor diff erent handling positions.
In each step of the procedure, the operator is able to know the charging status of cannula and stylet. |
|
Two Firing Modes |
 |
A mode: releases cannula and stylet in rapid sequence and captures tissue sample simultaneously. |
 |
D mode: releases stylet and allows the user to wait the required time before to release the cannula by pushing the button till the point A. |
|
|
Length |
Size 14G |
Size 16G |
Size 18G |
Size 20G |
100mm |
TY1410 |
TY1610 |
TY1810 |
TY2010 |
120mm |
TY1412 |
TY1612 |
TY1812 |
TY2012 |
160mm |
TY1416 |
TY1616 |
TY1816 |
TY2016 |
200mm |
TY1420 |
TY1620 |
TY1820 |
TY2020 |
250mm |
- |
- |
TY1825 |
|
300mm |
- |
- |
TY1830 |
|
|
|
|
Themy(R) can be provided with a coaxial introducer needle that allow execution of multiple procedures (code TYC ) |
|
Code with Coaxial included |
Single Coaxial Needle Code |
Coaxial Cannula Length |
TYC1410 |
PT13044 |
44mm |
TYC1412 |
PT13064 |
64mm |
TYC1416 |
PT13104 |
104mm |
TYC1420 |
PT13144 |
144mm |
TYC1610 |
PT15044 |
44mm |
TYC1612 |
PT15064 |
64mm |
TYC1616 |
PT15104 |
104mm |
TYC1620 |
PT15144 |
144mm |
TYC1810 |
PT17044 |
44mm |
TYC1812 |
PT17064 |
64mm |
TYC1816 |
PT17104 |
104mm |
TYC1820 |
PT17144 |
144mm |
TYC1825 |
PT17194 |
194mm |
TYC1830 |
PT17244 |
244mm |
TYC2010 |
PT19044 |
44mm |
TYC2012 |
PT19064 |
64mm |
TYC2016 |
PT19104 |
104mm |
TYC2020 |
PT19144 |
144mm |
|
|
|
 |
|
|
|
Intro |
|
Coaxial Introducer Needle |
Intro (PT) is a introducer coaxial needle used as an insertion guid of cannulas, biopsy devices, catheters, breast localization wires or other devices in the human body.
Intro needle allows the execution of multiple procedures remaining into the patient, while the biopsy needle, going through the introducer needle, can be unloaded and reloaded.
Intro is equipped with stylet with trocar tip designed to have a tissue penetration less traumatic as possible.
Stylet hub coloured according to the international colour code. Universal connector Luer-lock and handle made with transparent plastic material to facilitate the fluid passage visibility.
Centimeter markings and sliding stopper to easily determinate the insertion depth with a maximum safety for the patient. |
|
Code |
Outer Diameter |
Inside Diameter |
Length |
Gauge of the Needle to Introduce |
PT1305 |
13G |
2.17 |
50 mm |
14G |
PT13075 |
13G |
2.17 |
75 mm |
14G |
PT13095 |
13G |
2.17 |
95 mm |
14G |
PT13110 |
13G |
2.17 |
110 mm |
14G |
PT13140 |
13G |
2.17 |
140 mm |
14G |
PT1505 |
15G |
1.70 |
50 mm |
16G |
PT15075 |
15G |
1.70 |
75 mm |
16G |
PT15095 |
15G |
1.70 |
95 mm |
16G |
PT15110 |
15G |
1.70 |
110 mm |
16G |
PT15140 |
15G |
1.70 |
140 mm |
16G |
PT1705 |
17G |
1.32 |
50 mm |
18G |
PT17075 |
17G |
1.32 |
75 mm |
18G |
PT17095 |
17G |
1.32 |
95 mm |
18G |
PT17140 |
17G |
1.32 |
140 mm |
18G |
|
|
|
 |
|
|
|
Palium |
|
Automatic reusable device for soft tissues biopsy |
Palium is an automatic, reusable device equipped with a sequential advancement system of cannula and stylet.
Designed to get an high quality of the core specimen. Ultra-sharp tips and polished surfaces for a better entry and exit.
Powerful dual spring system for consistent and excellent core samples. Rapid-fi re action. Small size and lightweight. One hand activation to provide easy access to the tissue sample. Dual penetration depths for fl exibility and convenience (22mm or 15mm).
The samples can be taken with just one fi ring of the button. Can be easly armed with just one hand. May be sterilized with conventional methods. |
|
Features a side entry for FastCut needle spacer |
 |
Safety to avoid accidental fi ring. |
 |
Trigger site on the rear. |
 |
Security button. |
|
|
Use exclusively with FastCutM, MDL's needle.
Sequential loading system that requires a slight activation force. Advancement lengths: 15 - 22mm. |
|
 |
|
|
|
FastCutM |
Tru-cut needle for Soft Tissues Biopsy to use with Automatic Gun Type Magnum® Bard® |
FastCutM is a tru-cut disposable biopsy needle studied for use with Palium and also suitable for use with Bard® Magnum® reusable gun. |
|
The device, is equipped with |
 |
Cannula made with AISI 304 steel |
 |
"Menghini" sharpening that allows an atraumatic precise cutting of the tissue |
|
|
Centimeter markings and sliding stopper on the cannula surface to easily determinate the insertion depth with the maximum safety for the patient.
The handle is provided with a Luer connection to allow the connection to the syringe for aspiration.
Needle size with international colour code stamped on the spacer and on the primary packaging. |
|
The stylet has |
 |
A triple ultra-sharp tip to penetrate easily also into fi brous tissues. |
 |
A 20mm specimen notch for the sample capture. |
|
|
Optional a coaxial cannula for multiple procedures performing is inserted into the packaging (MGC code).
Surface echogenic marker enhances the ultrasound visibility. The set includes a spacer with side entry to facilitate the positioning of the needle into the automatic system.
It is suitable for stereotactic procedure. |
|
Code Needle without Coaxial |
Gauge X Length |
Coaxial Length |
OD/ID Coaxial |
Coaxial Code |
Code Item with Coaxial |
MG1210 |
12G X 100 mm |
44mm |
2.50/2.17mm |
PT11044 |
MGC1210 |
MG1213 |
12G X 130 mm |
74mm |
2.50/2.17mm |
PT11074 |
MGC1213 |
MG1215 |
12G X 150 mm |
94mm |
2.50/2.17mm |
PT11094 |
MGC1215 |
MG1216 |
12G X 160 mm |
104mm |
2.50/2.17mm |
PT11104 |
MGC1216 |
MG1220 |
12G X 200 mm |
144mm |
2.50/2.17mm |
PT11144 |
MGC1220 |
MG1410 |
14G X 100 mm |
48.5mm |
2.42/2.17mm |
PT13048 |
MGC1410 |
MG1413 |
14G X 130 mm |
78.5mm |
2.42/2.17mm |
PT13078 |
MGC1413 |
MG1416 |
14G X 160 mm |
108.5mm |
2.42/2.17mm |
PT13108 |
MGC1416 |
MG1420 |
14G X 200 mm |
148.5mm |
2.42/2.17mm |
PT13148 |
MGC1420 |
MG1610 |
16G X 100 mm |
48mm |
1.93/1.70mm |
PT15048 |
MGC1610 |
MG1613 |
16G X 130 mm |
78mm |
1.93/1.70mm |
PT15078 |
MGC1613 |
MG1615 |
16G X 150 mm |
98mm |
1.93/1.70mm |
PT15098 |
MGC1615 |
MG1616 |
16G X 160 mm |
108mm |
1.93/1.70mm |
PT15108 |
MGC1616 |
MG1620 |
16G X 200 mm |
148mm |
1.93/1.70mm |
PT15148 |
MGC1620 |
MG1810 |
18G X 100 mm |
48mm |
1.52/1.32mm |
PT17048 |
MGC1810 |
MG1813 |
18G X 130 mm |
78mm |
1.52/1.32mm |
PT17078 |
MGC1813 |
MG1815 |
18G X 150 mm |
98mm |
1.52/1.32mm |
PT17098 |
MGC1815 |
MG1816 |
18G X 160 mm |
108mm |
1.52/1.32mm |
PT17108 |
MGC1816 |
MG1820 |
18G X 200 mm |
148mm |
1.52/1.32mm |
PT17148 |
MGC1820 |
MG1825 |
18G X 250 mm |
198mm |
1.52/1.32mm |
PT17198 |
MGC1825 |
MG1830 |
18G X 300 mm |
248mm |
1.52/1.32mm |
PT17248 |
MGC1830 |
MG2010 |
20G X 100 mm |
48mm |
1.13/0.95mm |
PT19048 |
MGC2010 |
MG2013 |
20G X 130 mm |
78mm |
1.13/0.95mm |
PT19078 |
MGC2013 |
MG2016 |
20G X 160 mm |
108mm |
1.13/0.95mm |
PT19108 |
MGC2016 |
MG2020 |
20G X 200 mm |
148mm |
1.13/0.95mm |
PT19148 |
MGC2020 |
|
|
|
 |
|
|
|
FastCutP |
Tru-Cut Needle for Soft Tissues Biopsy to use with Automatic Gun Type PRO_MAG 2.5TM |
FastCutP (MGP) is a tru-cut disposable biopsy needle for Pro-Mag 2.5TM |
|
The device, is equipped with |
 |
Cannula made with AISI 304 steel |
 |
"Menghini" sharpening that allows an atraumatic precise cutting of the tissue |
|
|
Centimeter markings and sliding stopper on the cannula surface to easily determine the insertion depth with the maximum safety for the patient.
Needle size with international colour code stamped on the spacer and on the primary packaging. |
|
The stylet has |
 |
A triple ultra-sharp tip to penetrate easily also into fi brous tissues. |
 |
A 20mm specimen notch for the sample capture. |
|
|
Code without Coaxial |
Gauge X Length |
Coaxial Length |
OD/ID Coaxial |
Code Coaxial |
Code Item with Coaxial |
MGP1410 |
14G X 100mm |
44.5mm |
2.42/2.17mm |
PT13044 |
MGPC1410 |
MGP1412 |
14G X 120mm |
64.5mm |
2.42/2.17mm |
PT13064 |
MGPC1412 |
MGP1416 |
14G X 160mm |
104.5mm |
2.42/2.17mm |
PT13104 |
MGPC1416 |
MGP1420 |
14G X 200mm |
144.5mm |
2.42/2.17mm |
PT13144 |
MGPC1420 |
MGP1610 |
16G X 100mm |
44mm |
1.93/1.70mm |
PT15044 |
MGPC1610 |
MGP1612 |
16G X 120mm |
64mm |
1.93/1.70mm |
PT15064 |
MGPC1612 |
MGP1616 |
16G X 160mm |
104mm |
1.93/1.70mm |
PT15104 |
MGPC1616 |
MGP1620 |
16G X 200mm |
144mm |
1.93/1.70mm |
PT15144 |
MGPC1620 |
MGP1810 |
18G X 100mm |
44mm |
1.52/1.32mm |
PT17044 |
MGPC1810 |
MGP1812 |
18G X 120mm |
64mm |
1.52/1.32mm |
PT17064 |
MGPC1812 |
MGP1816 |
18G X 160mm |
104mm |
1.52/1.32mm |
PT17104 |
MGPC1816 |
MGP1820 |
18G X 200mm |
144mm |
1.52/1.32mm |
PT17144 |
MGPC1820 |
MGP1825 |
18G X 250mm |
194mm |
1.52/1.32mm |
PT17194 |
MGPC1825 |
MGP1830 |
18G X 300mm |
244mm |
1.52/1.32mm |
PT17244 |
MGPC1830 |
MGP2010 |
20G X 100mm |
44mm |
1.13/0.95mm |
PT19044 |
MGPC2010 |
MGP2012 |
20G X 120mm |
64mm |
1.13/0.95mm |
PT19064 |
MGPC2012 |
MGP2016 |
20G X 160mm |
104mm |
1.13/0.95mm |
PT19104 |
MGPC2016 |
MGP2020 |
20G X 200mm |
144mm |
1.13/0.95mm |
PT19144 |
MGPC2020 |
|
|
|
 |
|
|
|
|
|
|
|